MS2308 Earth Resistance Tester
Features
*2 pole resistance measurement.
*3 pole & 4 pole earth resistance mearurement.
*4 pole soil resistivity testing.
*Current Clamp selection method is used to measuring earth resistance without breaking grounding connection.
*Double clamp without auxiliary electrode is used to fast measuring grounding resistance.
*Automatic frequency control (AFC) is automatically identified interference frequency and then selected the proper measurement frequency, so that reduced the affect of interference voltage.
*Automatically measuring the interference voltage and the leakage current. The limited value will be alarmed.
*Auto power off
*Clock display
*Double battery power supply and low battery indication.
*Data storage function and uploading to PC by USB 2.0 interface.
Specifications | |
function | |
3 Pole & 4 Pole | Voltage:AC20/48V |
Frequency:94Hz,105Hz,111Hz,128Hz,AFC. | |
Resistance:0.02Ω~300KΩ±(5%rdg+5dgt) | |
3 Pole & 4 Pole With | Voltage:AC20/48V |
Current Clamp | Frequency:94Hz,105Hz,111Hz,128Hz,AFC. |
Resistance:0.02Ω~19.99KΩ±(5%rdg+5dgt) | |
Double Clamp | Voltage:AC48V |
Frequency:94Hz,105Hz,111Hz,128Hz,AFC. | |
Resistance:0.02Ω~140Ω±(10%rdg+5dgt) | |
R~2 Pole | Voltage:AC20V |
Frequency:94Hz,105Hz,111Hz,128Hz,AFC. | |
Resistance:0.02Ω~300kΩ±(5%rdg+5dgt) | |
R~2/4 Pole | Voltage:AC20V |
Resistance:0.02Ω~3kΩ±(5%rdg+5dgt) | |
Rk(Compensation mea- | Voltage:AC20/48V/DC20V |
surement for Wire resistance | Frequency:94Hz,105Hz,111Hz,128Hz,AFC. |
Resistance:0.02Ω~29.99Ω±(5%rdg+5dgt) | |
Test Short Current | ≤250mA |
Soil Resistivity | Voltage:AC20/48V |
Frequency:94Hz,105Hz,111Hz,128Hz,AFC. | |
Range:1Ωm~9999kΩm±(5%rdg+5dgt) | |
Disturd Voltage | Voltage:±1V~±50VDC/AC±5%rdg+5dgt |
Current and Frequency | Frequency:16Hz~400Hz±1%rdg+2dgt |
Current:20mA~2A;±5%rdg+5dgt | |
USB2.0 interface | |
Data Storage | Manually store 100 groups |
Power supply | LR14x6;Voltage:9V |
Recharge Battery:Nl~MH recharge Battery 7.2V | |
Charger: Input voltage:100V~240V Frequency: | |
50Hz~60Hz Output voltage:12VDC 3A | |
Display | LCD display, with Back light,Max 9999 |
Dimension | 230(W)x125(H)x284(L)mm |
Weight | Approx.2.5kg |